Ruud furnace keeps blowing 24 VAC 2 Amp fuse within 12 hours
Help!
20 year old Ruud 90 Plus condensing gas furnace with JCI G961DAJ-2401 controller keeps blowing its 24V AC 2 Amp fuse. I tightened the wires, nothing looks wrong.
I measured the current for each step:
mA Step 84 Start. No call for heat. 260 Draft induction motor on. 770 Gas valve open, flame on 880 Blower motor on 300 Gas valve closed 84 Blower motor off
Photos:
https://photos.app.goo.gl/63jWLBLmiqGFB56U8
I am measuring the current in series with the inline fuse from the 24V AC transformer on its way to the Johnson Controls controller board.
I’m stuck. Any ideas?